Skip to content
Mon–Sat 8 AM–7 PM · Sunday closedBook online: up to $50 off HVAC repairs, up to $22 off appliance repairs
LarchHVAC & Appliance
EN
Text us (509) 370-5361

Newman Lake · cabins turned year-round

Newman Lake heat pump repair when aux heat won’t quit

Most heat pumps around Newman Lake are recent, put in to retire electric furnaces and baseboards. When one misbehaves, the thermostat tells you first: aux heat for hours, a defrost that never ends, a compressor that will not start at 5°F.

Thirty-five minutes
Trent Avenue to Starr Road, or the Barker exit off I-90 and north.
Thermostat first
Changeover, lockout and aux heat logic checked before the outdoor unit.
Cabin circuits
Undersized services feeding strips and heat pumps tested under load.
Our technician working on an outdoor AC unit
4.6 on Google · 100+ reviewsFormerly Adam & Sam Brothers Repair
$99 diagnosticCounted inside the written repair price you approve. Say no to the repair and it is the whole bill.
Up to $50 offAn HVAC repair booked online. Appliance repairs booked online: up to $22 off. Never taken off the diagnostic.
Same dayNo heat, no cooling or a warm refrigerator: same-day windows Monday through Saturday.

Cabins along Newman Lake Drive, out past Moab and around to the Hauser end by the state line, became year-round homes heated by electric furnaces and baseboards. Over the past decade many swapped those for cold-climate heat pumps and ductless systems, keeping the strips or the old furnace as backup. It is colder here in January than in Spokane, so when one of those heat pumps fails, it fails in a particular way: the house stays warm and the bill doubles. The outdoor unit quits, the thermostat quietly hands the job to the strips, and nobody notices until the Avista statement arrives.

The visit starts at the thermostat, because the control settings decide whether the outdoor unit ever gets a chance to run. We check changeover and lockout temperatures and the aux heat logic, then go outside with a meter: capacitor, contactor, compressor and fan amperage, crankcase heater, defrost board and sensor readings. The crankcase heater matters more here than in town: it keeps compressor oil from thickening on bitter nights, and when it fails, the compressor struggles to start. Gauges go on next, with pressures read against the cold rather than a summer chart, and on a cold morning we stand and watch an entire defrost cycle instead of assuming it works. Indoors, the strips, their sequencers and the blower are metered. Only then is a price written, a single figure that already counts the $99 diagnostic.

Newman Lake symptoms, cold-season first

What you noticeWhat it usually isWhat we do
Aux or emergency heat on for days, bill climbingOutdoor unit not running, low charge, or lockout set too highOutdoor fault repaired, charge corrected, lockout and changeover reset
Outdoor unit iced for daysDefrost board or sensor failed, slow fan motor, or a low chargeCoil thawed and cleaned, defrost control repaired, charge verified
Cool air in heating modeA reversing valve hung up between modes, or a defrost cycle that runs too longValve or solenoid replaced, defrost timing checked
No heat from the heat pump below about 10°FStandard model past its rated range, or crankcase heater and start parts failingComponents replaced; plain talk if it was never a cold-climate unit
Warm air in July, outdoor fan silentCapacitor or contactor failure, or a fan motor stuck fastReplaced on the spot, amperage checked
Burnt smell at the disconnect, or breaker tripsCompressor drawing too much, shorted motor, or a cabin circuit too small for the stripsEquipment repaired on the visit; a circuit problem is shown to you in writing

The January that ran on strips

A year-round home on Newman Lake Drive ran on auxiliary heat for most of a January because a defrost sensor had failed and the outdoor coil had iced over against the wind off the lake. The heat pump itself was fine; it simply could not breathe. Replacing the sensor, thawing and cleaning the coil, and confirming the charge returned the heat pump to its job, and the strips to standby for the bitterest mornings. That is the most common Newman Lake story we hear, and it usually starts with an aux heat light that has been on for a week.

Another conversation comes up when the heat pump was never a cold-climate model. Standard units lose much of their output below about 20 to 25°F, and no repair changes that. We tell you plainly whether you have a fault or a mismatch, and when it is a mismatch you get a written replacement figure next to the repair number; the install site visit for that replacement carries no charge. Line sets running across a cabin wall also tend to leak at flare joints, so the gauges always go on. Summer still brings the usual capacitor failures on the first hot week. Mitsubishi, Daikin and Fujitsu ductless units are as common here as Carrier, Bryant, Trane, Lennox, Rheem and Goodman ducted systems.

Electrical services on older cabins around Starr Road are often modest, and a heat pump plus a strip bank pushes them hard. The technician tests the breaker, the disconnect and the circuit during diagnosis and tells you when the fault is in the cabin’s wiring rather than the heat pump. Ductless heads inside the cabin get checked too, since a clogged filter on a wall unit can make the outdoor section look weak. Newman Lake is about thirty-five minutes east of the shop, covered alongside Otis Orchards and the east Valley, with no distance surcharge.

Outdoor AC condenser opened up for testing beside a Spokane house

Typical Newman Lake repair costs

A defrost board starts at $250. A failed electric heat strip, which often burns out after months as the only heat source, starts at $200, and replacing an outdoor fan motor slowed by ice begins at $350. Each is a starting price for the Spokane area, not a quote. Your written number comes after the testing is done, the $99 already in it, and a written warranty covers the finished work. Ordered parts bring no second trip fee, even at the far end of the lake.

RepairPrice
Heat pump defrost boardfrom $250
Electric heat strip / elementfrom $200
Outdoor fan motorfrom $350
AC / heat pump capacitorfrom $150
Contactorfrom $175
Heat pump reversing valvefrom $900
Refrigerant leak repair and rechargefrom $400
Indoor (evaporator) coilfrom $1,200

Starting prices in the Spokane area for 2026, part and work included. Not a quote: your exact price is in the written estimate after the $99 diagnostic.

See all prices

Questions we hear

Can you reach Newman Lake the same day if the heat pump quits in a cold snap?

A no-heat call earns a same-day window, Monday through Saturday, and Newman Lake sits inside our 35-minute map with no distance surcharge. Call or text early and we usually make it out that day. If the strips are carrying the house you are warm but paying for it, and we still treat the call as a priority.

Our aux heat light has been on for a week. Is that normal in January?

Short bursts of aux heat on the coldest mornings are expected. Hours or days of it mean the outdoor unit is not pulling its weight: usually a defrost fault, an iced coil, a refrigerant leak, or a lockout temperature set too high at the thermostat. The sooner it is diagnosed, the smaller the electric bill that follows.

The outdoor unit has been frozen solid for days. Should we chip the ice off?

No. Chipping can bend the fins and puncture the coil. Put the system on emergency heat and let the strips hold the house, clear loose snow from around the unit, and call us. A healthy heat pump defrosts itself several times a day; one that stays frozen has a defrost board, sensor, fan or charge problem.

Should we repair a heat pump that was never a cold-climate model?

It depends on the fault. A capacitor or defrost sensor on a standard unit is worth fixing; it will still cool well and heat through spring and fall. If the complaint is that it cannot keep up below 20°F, that is a design limit, and we say so and give you a written replacement number to compare against the repair.

Do you do the refrigerant work yourselves?

Yes. EPA 608 Universal certification is standard on our crew, and every van has a recovery machine, gauges and electronic leak detection for R-410A, R-22, R-32 and R-454B. Leaks are repaired before any recharge, the charge is weighed to the nameplate amount, and the readings go on your written invoice.

Call, text or book

If your aux heat light has been on for days or the outdoor unit is frozen, call or text us; a photo of the thermostat screen helps. Your written repair price absorbs the $99 diagnostic, and online bookings carry up to $50 off an HVAC repair booked online.

Book a visit

Tell us what is going on

We call or text back to confirm a time window, usually the same day.

  • $99 diagnostic Counted inside the written repair price you approve. Say no to the repair and it is the whole bill.
  • Up to $50 off An HVAC repair booked online. Appliance repairs booked online: up to $22 off. Never taken off the diagnostic.
  • Up to $500 off A full-system install booked through our site-visit form, first-year tune-up included. The site visit costs nothing.

Prefer to text? Send a photo of the model tag to (509) 370-5361.

How should we reach you?

Booked online: up to $50 off an HVAC repair or up to $22 off an appliance repair, never off the $99 diagnostic. Full-system installs: up to $500 off.

CallTextBook